Home
Products and R&D
Products Center
Non-cryotherapy Products
Disposable Multichannel Laparoscopic Access Platform


Single-port laparoscopy(SPL) brings more freedom and safety, and is more minimally invasive compared with traditional laparoscopy, which has been applied in more clinical departments. Its value stands out with the extensive application of robotic surgeries.


Radical Prostatectomy
Radical Cystectomy
Kidney transplant
Gynaecological surgery
General surgery
Gallbladder surgery
Liver surgery
Back surgery
Colorectal surgery
Transanal Total Mesorectal Excision(TATME)
Transabdominal Preperitoneal(TAPP)
Ovarian Cystectomy
Myomectomy
Ectopic pregnancy
Endometriosis
Cervical cerclage
Laparoscopically assisted vaginal hysterectomy
Sacrocolpopexy
Vaginal hysterectomy
Nephrectomy
Cystectomy
Adrenalectomy
Laparoscopic renal cyst decortication
Ureteroscopy
Prostatectomy
Appendicitis
Ureteral malformation
Inguinal hernia
Gallstones
Cholelithiasis
Hydronephrosis
Mediastinoscopy
1. Less cutting of skin to reduce scarring and ensure beautiful healing
2. Small wounds to reduce infections
3. Easy collection of specimens by single cut
4. Less pain and bleeding
5. Faster recovery and shorter hospital stay
5 trocar sleeves are available
Position and direction of trocar sleeves are free to choose
Position and direction of trocar sleeves are adjustable during the operation
3 surgical alternatives are supported including single-port, reduced-port or hand-assisted laparoscopic surgery
Robotic introducer needle is inserted freely into the single-port platform, and the position of the trocar sleeve is adjusted according to the surgical requirements
Reduce surgical cuts to ensure beautiful healing
Laparoscopic instruments can improve stability and accuracy of operation based on the lever principle through the membrane
Small wounds and less bleeding to reduce complications
Single-port platform and wound retractor can be separated during the operation to facilitate specimen collection
Laparoscopic devices are free to add anytime during the operation
Various surgical needs and collocations can be fulfilled with trocar sleeves for 5mm instruments, 5-12mm instruments and 10mm laparoscopic instruments
[Specification]
Model | Product Composition | Recommended Incision Size | |||
Single-port Platform (DK) | Trocar (CCQ) | Wound Protector | |||
Sleeve (CCTG) | Introducer Needle (CCZ) | ||||
SC130-55 | 1 × DK-55 | 2 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-45 | 1.5-3cm |
SC130-75 | 1 × DK-75 | 2 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-65 | 1.5-6cm |
SC130-100 | 1 × DK-100 | 2 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-90 | 3-9cm |
SC130-55S | 1 × DK-55 | 2 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-45S | 1.5-2.5cm |
SC130-75S | 1 × DK-75 | 2 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-65S | 1.5-3cm |
SC130-100S | 1 × DK-100 | 2 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-90S | 1.5-6cm |
SC132-75 | 1 × DK-75 | 2 × CCTG-5 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-65 | 1.5-6cm |
SC132-100 | 1 × DK-100 | 2 × CCTG-5 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-90 | 3-9cm |
SC132-75S | 1 × DK-75 | 2 × CCTG-5 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-65S | 1.5-3cm |
SC132-100S | 1 × DK-100 | 2 × CCTG-5 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-90S | 1.5-6cm |
SC133-55 | 1 × DK-55 | 1 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-45 | 1-3cm |
SC133-75 | 1 × DK-75 | 1 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-65 | 1.5-6cm |
SC133-100 | 1 × DK-100 | 1 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-90 | 3-9cm |
SC133-55S | 1 × DK-55 | 1 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-45S | 1.5-2.5cm |
SC133-75S | 1 × DK-75 | 1 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-65S | 1.5-3cm |
SC133-100S | 1 × DK-100 | 1 × CCTG-5 1 × CCTG-10 1 × CCTG-12 | 1 × CCZ-5 1 × CCZ-10 | 1 × SS110-90S | 1.5-6cm |
SC134-55 | 1 × DK-55 | 3 × CCTG-5 | 1 × CCZ-5 | 1 × SS110-45 | 1-3cm |
SC134-75 | 1 × DK-75 | 3 × CCTG-5 | 1 × CCZ-5 | 1 × SS110-65 | 1.5-6cm |
SC134-100 | 1 × DK-100 | 3 × CCTG-5 | 1 × CCZ-5 | 1 × SS110-90 | 3-9cm |
SC134-55S | 1 × DK-55 | 3 × CCTG-5 | 1 × CCZ-5 | 1 × SS110-45S | 1.5-2.5cm |
SC134-75S | 1 × DK-75 | 3 × CCTG-5 | 1 × CCZ-5 | 1 × SS110-65S | 1.5-3cm |
SC134-100S | 1 × DK-100 | 3 × CCTG-5 | 1 × CCZ-5 | 1 × SS110-90S | 1.5-6cm |
[Warnings]
1. The device is designed and intended for single use only. DO NOT RESTERILIZE AND/OR REUSE. Reuse or resterilisation may create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not limited to the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness or death of the patient. Reuse or resterilisation may compromise the structural integrity of the device and/or lead to device failure which, in turn, may result in patient injury, illness and death. The manufacturer will not be responsible for any direct, incidental or consequential damages resulting from resterilisation or reuse.
2. Please carefully read all instructions prior to use. Failure to observe all warnings and precautions may result in complications.
3. Inspect the device, prior to procedure, to verify functionality and lack of damaged parts. Do not use the device if the outer or the inner package is damaged or opened or if the components appear to be damaged or defective.
4. Use before the expiry date.
5. After use, the product may be a potential biohazard. Handle and dispose of in accordance with acceptable medical practice and applicable local, state, and federal laws and regulations related to product contamination by blood.
[Precautions for Use]
1. The product shall be used by surgeons in medical institutions.
2. The trocar-5 is only applicable for instruments with a diameter of 5mm. The trocar-10 is only applicable for instruments with a diameter of 5~10mm. The trocar-12 is only applicable for endoscope with a diameter of 10mm.
3. This device is intended for single (one) use – only. Do not re-sterilize and/or reuse, as this can potentially result in compromised device performance and increase risk of complications (patient infection, transmission of infectious disease, etc.).
4. Lubrication of the rods of surgical instruments is recommended. Use of lubricant may ease placement of surgical instruments. Use of iodophor or sterile paraffin oil is recommended.
CAUTION:Indications, contraindications, warnings and instructions for use can be found in the product IFU supplied with each device. Information for use only in countries with applicable health authority registrations. Products shown for INFORMATION purposes only and may not be approved or for sale in certain countries. Please check availability with your local sales representative or customer service.